Panasonic R410a Air Conditioner User Manual
Nuance power pdf advanced user manual. The guide also includes tips and notes to help you use the software more effectively.Be sure to also take advantage of our illustrated workbook.
Installation instructions, W-2way system air conditioner, For refrigerant r410a
- Panasonic Inverter Air Conditioner User Manual
- Panasonic R410a Air Conditioner Manual
- Panasonic Inverter Air Conditioner Manual Australia
- Panasonic Inverter Air Conditioner R410a Manual
- Panasonic Air Conditioner Remote Manual
Panasonic inverter AC R410A timer light keeps blinking. Customer Question. I have a panasonic air-conditioner which was installed in June 2011 and the timer light is flashing on the unit and I can't turn it off or operate the unit. The unit has set itself to timer and I have followed the manual to cancel the timer - but the unit is not. Inverter Split system Air Conditioner R410A. Shinco Service Manual - 2 - Table of contents Part I 1. Introductions of Part Names and Functions 2. Outline Dimension of Indoor and Outdoor Units 3. Specification 4. Wiring Diagram. Panasonic(rotary type DC INVERTER) Panasonic(rotary type.
X
A
U
D
T
K
Outdoor Units
85464359982001 ©SANYO 2006
SANYO Electric Co., Ltd.
Gunma, Japan
– W-2WAY System Air Conditioner –
■ R410A Models
Indoor Units
Class
7
9
12
18
24
36
48
X
4-Way Air Discharge Semi-Concealed Type
XHX1252
XHX1852
XHX2452
XHX3652
A
1-Way Air Discharge Semi-Concealed Type
AHX0752
AHX0952
AHX1252
U
Concealed Duct Type
UHX0752
UHX1252
UHX1852
UHX2452
UHX3652
D
Concealed Duct
DHX3652
DHX4852
High-Static Pressure Type
Panasonic Inverter Air Conditioner User Manual
T
Ceiling-Mounted Type
THX1252
THX1852
THX2452
K
Wall-Mounted Type
KHX0752
KHX0952
KHX1252
KHX1852
Panasonic R410a Air Conditioner Manual
KHX2452
for Refrigerant R410A
Panasonic Inverter Air Conditioner Manual Australia
* Refrigerant R410A is used in the outdoor units.
INSTALLATION INSTRUCTIONS
Class
90
140
C
ECO-i W-2WAY
CHDX09053 CHDX14053
Optional Controllers
Timer Wired Remote Controller
RCS-TM80BG
Wireless Remote Controller (For U, D Type)
RCS-BH80AAB.WL
Wireless Remote Controller (For X Type)
RCS-SH80AAB.WL
Wireless Remote Controller (For A, T Type)
RCS-TRP80AAB.WL
RC Wireless Remote Controller (For K Type)
RCS-SH1AAB
Simplified Remote Controller
RCS-KR1AGB
System Controller
SHA-KC64UG
Intelligent Controller
SHA-KT256BA
Communication Adaptor
SHA-KA128AAB
Remote Sensor
ART-K45AGB
LonWorks Interface
SHA-LN16UAB
07-007 W-2WAY_II_NA 1/23/07 6:09 PM Page a
Summary of the content on the page No. 1
TECHNICAL & SERVICE MANUAL
INDOOR UNIT : CS-MKS9NB4U & CZ-18BT1U
CS-MKS12NB4U & CZ-18BT1U
CS-KS18NB4UW & CZ-18BT1U
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
Indoor Model No. Product Code No.
Capacity
Body (Panel) Body (Panel)
9,000BTU / h CS-MKS9NB4U (CZ-18BT1U) 1 852 361 08 (1 852 361 15)
11,900BTU / h CS-MKS12NB4U (CZ-18BT1U) 1 852 361 09 (1 852 361 15)
17,500BTU / h CS-KS18NB4UW (CZ-18BT1U) 1 852 361 06 (1 852 361 15)
Semi-Concealed Type Indoor Unit
Body
< Applicable Multi-Outdoor Units
Summary of the content on the page No. 2
SAFETY PRECAUTIONS • Before doing repair work, please read the ' SAFETY PRECAUTIONS' carefully and fully understand them. • The precautionary items here are divided into ' Warning' and ' Caution' items. Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly, are included in the ' Warning' table. However, even precautionary items identified as ' Caution' also have the potential for serious consequences if
Summary of the content on the page No. 3
Warning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. Prohibit If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle. If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle, which may cause a unit breakdown.' Prohibit When th
Panasonic Inverter Air Conditioner R410a Manual
Summary of the content on the page No. 4
TABLE OF CONTENTS Page ....................................................... 2 SAFETY PRECAUTIONS .......................................................... 4 TABLE OF CONTENTS .......................................... 6 APPLICABLE MULTI-OUTDOOR UNITS ..........................................
Summary of the content on the page No. 5
Page .............................................. A-4 APPENDIX D Operating Instructions (CZ-RD515U) ...................................... A-5 APPENDIX E INSTALLATION INSTRUCTIONS (CZ-RD515U) 5
Summary of the content on the page No. 6
APPLICABLE MULTI-OUTDOOR UNITS Multi-Outdoor Unit 3-Room 4-Room 4-Room CU-3KS19NBU CU-4KS24NBU CU-4KS31NBU Indoor Unit CS-MKS9NB4U & CZ-18BT1U YES YES YES CS-MKS12NB4U & CZ-18BT1U YES YES YES CS-KS18NB4UW & CZ-18BT1U YES YES YES 6
Summary of the content on the page No. 7
1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F DB / 71 °F WB 115 °F DB Cooling Minimum 67 °F DB / 57 °F WB 14 °F DB 7
Summary of the content on the page No. 8
2. SPECIFICATIONS 2-1. Unit Specifications 2-1-1. Indoor Unit CS-MKS9NB4U & CZ-18BT1U <230V> Type Semi-Concealed Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Cooling Total Capacity BTU/h 9,000 kW 2.65 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 221(376)/206(350)/194(330) Moisture Removal (High) Pints/h 3.4 Available Voltage Range V 187 to 253 Running Amperes A 0.1 Power Input W 16 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Contr
Summary of the content on the page No. 9
Indoor Unit CS-MKS9NB4U & CZ-18BT1U <208V> Type Semi-Concealed Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Cooling Total Capacity BTU/h 9,000 kW 2.65 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 221(376)/206(350)/194(330) Moisture Removal (High) Pints/h 3.4 Available Voltage Range V 187 to 253 Running Amperes A 0.11 Power Input W 15 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF Timer, 1-Hour OFF
Summary of the content on the page No. 10
Indoor Unit CS-MKS12NB4U & CZ-18BT1U <230V> Type Semi-Concealed Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Cooling Total Capacity BTU/h 11,900 kW 3.5 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 235(399)/206(350)/194(330) Moisture Removal (High) Pints/h 4.26 Available Voltage Range V 187 to 253 Running Amperes A 0.11 Power Input W 17 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF Timer, 1-Hour O
Summary of the content on the page No. 11
Indoor Unit CS-MKS12NB4U & CZ-18BT1U <208V> Type Semi-Concealed Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Cooling Total Capacity BTU/h 11,900 kW 3.5 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 235(399)/206(350)/194(330) Moisture Removal (High) Pints/h 4.26 Available Voltage Range V 187 to 253 Running Amperes A 0.12 Power Input W 16 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF Timer, 1-Hour O
Summary of the content on the page No. 12
Indoor Unit CS-KS18NB4UW & CZ-18BT1U <230V> Type Semi-Concealed Type Indoor Unit Voltage Rating 230V Single-Phase 60Hz Cooling Total Capacity BTU/h 17,500 kW 5.15 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 341(579)/294(500)/253(430) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 253 Running Amperes A 0.15 Power Input W 22 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF Timer, 1-Hour
Summary of the content on the page No. 13
Panasonic Air Conditioner Remote Manual
Indoor Unit CS-KS18NB4UW & CZ-18BT1U <208V> Type Semi-Concealed Type Indoor Unit Voltage Rating 208V Single-Phase 60Hz Cooling Total Capacity BTU/h 17,500 kW 5.15 3 3 Air Circulation (Hi/Me/Lo) ft /min (m /h) 341(579)/294(500)/253(430) Moisture Removal (High) Pints/h 4.89 Available Voltage Range V 187 to 253 Running Amperes A 0.16 Power Input W 22 -- Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF Timer, 1-Hour
Summary of the content on the page No. 14
2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor Unit (Body) CS-MKS9NB4U Control PCB Part No. CB-CS-MKS9NB4U Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Turbo Q'ty .. Dia. and Length inch (mm) 1 .. D12-5/8 / L5-3/4 (D322/L147) Fan Motor Type DC Motor Model .. Q'ty SIC-62FW-D866-2 .. 1 No. of Poles 8 Rough Measure RPM (Cool) 440 Rating Voltage / Nominal Output DC280V / 23W Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Contr
Summary of the content on the page No. 15
Indoor Unit (Body) CS-MKS12NB4U Control PCB Part No. CB-CS-MKS12NB4U Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Turbo Q'ty .. Dia. and Length inch (mm) 1 .. D12-5/8 / L5-3/4 (D322/L147) Fan Motor Type DC Motor Model .. Q'ty SIC-62FW-D866-2 .. 1 No. of Poles 8 Rough Measure RPM (Cool) 470 Rating Voltage / Nominal Output DC280V / 23W Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Thermal Fuse Over- Current Protection Yes Over- Heat Protection Yes Ru
Summary of the content on the page No. 16
Indoor Unit (Body) CS-KS18NB4UW Control PCB Part No. CB-CS-KS18NB4U Controls Microprocessor Control Circuit Fuse 250V 3A Fan Type Turbo Q'ty .. Dia. and Length inch (mm) 1 .. D12-5/8 / L5-3/4 (D322/L147) Fan Motor Type DC Motor Model .. Q'ty SIC-62FW-D866-2 .. 1 No. of Poles 8 Rough Measure RPM (Cool) 650 Rating Voltage / Nominal Output DC340V / 20W Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over- Current Protection Yes Over- Heat Protection
Summary of the content on the page No. 17
2-3. Other Component Specifications Indoor Unit CS-MKS9NB4U & CZ-18BT1U CS-MKS12NB4U & CZ-18BT1U CS-KS18NB4UW & CZ-18BT1U • Indoor air temp sensor • Indoor heat exchanger sensor (Model:KTEC-35-S98) (Model:PT2M-51H-S3) 10 200 9 180 8 160 7 140 6 120 5 100 4 80 3 60 2 40 1 20 0 0 50 59 68 77 86 95 104 32 50 68 86 104 122 140 158 176 194 (10) (15) (20) (25) (30) (35) (40) (0) (10) (20) (30) (40) (50) (60) (70) (80) (90) Temperature °F (°C) Temperature °F (°C) 17 Resistance (k ohm) Resistanc
Summary of the content on the page No. 18
3. DIMENSIONAL DATA Indoor Unit CS-MKS9NB4U & CZ-18BT1U CS-MKS12NB4U & CZ-18BT1U CS-KS18NB4UW & CZ-18BT1U Unit : inch (mm) 18 A A 23-5/8 (600) Ceiling opening dimensions 21-1/32 (534) Suspension bolt pitch Air intake 1 Center of Discharge outlet 2 7 panel Refrigerant tubing (liquid tube) dia. 1/4' (flared) 3 Refrigerant tubing (gas tube) dia. 1/2' (flared) 8 4 4-29/32 5 Drain tube connection port VP20 (outer dia. 1') A View Power supply port 6 7 Suspension bolt hole (4 - 1/2' x 1-1/8' hole
Summary of the content on the page No. 19
4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram Indoor Unit CS-MKS9NB4U & CZ-18BT1U CS-MKS12NB4U & CZ-18BT1U Indoor unit O.D. 3/8' (9.52 mm) O.D. 1/4' (6.35 mm) Cooling cycle Indoor Unit CS-KS18NB4UW & CZ-18BT1U Indoor unit O.D. 1/2' (12.7 mm) O.D. 1/4' (6.35 mm) Cooling cycle 19 Strainer Strainer Heat exchanger Heat exchanger
Summary of the content on the page No. 20
5. ELECTRICAL DATA 5-1. Electric Wiring Diagrams Indoor Unit CS-MKS9NB4U & CZ-18BT1U CS-MKS12NB4U & CZ-18BT1U CS-KS18NB4UW & CZ-18BT1U 20 TO OUTDOOR UNIT 1 2 3 TERMINAL BASE FLAP (W) FLAP (R) IND LAMP ASSY 1 2 3 4 5 1 2 3 4 5 THERMISTOR 1 2 3 4 5 6 7 8 9 10 DRAIN PUMP 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 GND FAN MOTOR DP BRN FM RED ORG 1 2 3 4 5 6 YEL 1 2 3 4 5 6 PNK BLU VLT 1 2 3 4 5 6 1 3 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 1 2 3 4 5 6 7 1 2 3 4 5 1 3 1 2 1 2 1 2 3 4 5 6 1 3 1 2 3 4 5