  1. Add Drivers To Esxi Installer
  2. Vmware Nic Drivers

Emulex Drivers for VMware ESXi for LightPulse Adapters User Guide December 30, 2016 Chapter 2: Installation Native Mode Overview Chapter 2: Installation This section provides information for installing the ESXi driver for the FC, FCoE, and NIC protocols. 2.1 Native Mode Overview. Emulex Drivers Version 10.2 for VMware ESXi User Manual P010087-01A Rev. Introduction ESXi Compatibility 8 1. Introduction This product supports the Emulex® OneConnect™ and LightPulse® families of adapters. The VMware ESXi drivers support the Fibre Channel (FC), FC over Ethernet (FCoE). May 17, 2011  What is the process you guys are using to update your emulex hba firmware on esxi since the old console is no longer present? The firmware has more to do with the OS and driver compatibility than to update just because your firmware is out of date.

* RECOMMENDED * Emulex(BRCM) Fibre Channel over Ethernet driver for VMware vSphere 6.7

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type:Software - Storage Fibre Channel and Fibre Channel Over Ethernet
Version:2019.03.03(25 Jul 2019)
Operating System(s): VMware vSphere 6.7
Multi-part download
File name:cp040416.compsig (2.0 KB)
File name:cp040416.zip (1.1 MB)
VMware vSphere 6.7 Fibre Channel over Ethernet Driver kit for HPE Emulex(BRCM) Converged Network Adapters

Prerequisites:

Please consult SPOCK for a list of supported configurations available at the following link:

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change.

To obtain the guide:

  1. Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

#esxcli software vib remove lpfc

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

9712c3d5c75daf20560bb9b49f6f4ab1fa37b84a51dd6b8cf51adf35b7a90bcacp040416.zip
d5ea031931cbce8a639b488ef785be07d9795838c05c5e58e063ca30c2e982a4cp040416.compsig

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

To use Smart Update Manager from the Service Pack for ProLiant:

Remote Online, if the component is supported by SUM but is not yet part of an SPP:

  • Download the appropriate Service Pack for ProLiant
  • Add the component to the Service Pack for ProLiant
  • Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated
  • Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux
  • Add the ESXi host to be updated as a remote target/node
  • Enter the IP or DNS address of the ESXi host to be updated
  • Enter the ESXi host credentials (root or administrator username and password)
  • For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.
  • Follow Smart Update Manager Steps and complete the firmware update.
  • Refer to the Service Pack for ProLiant Documentation for detailed instructions at: www.hpe.com/servers/spp/download

To update the driver using VMware tools:

  • Unzip this HPE component to extract the driver offline bundle
  • Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.
  • Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands

End User License Agreements:
HPE Software License Agreement v1

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Important:

This component is intended to be used by HPE applications. It is a zip that contains the same driver deliverable available from the vmware.com and the HPE vibsdepot.hpe.com webpages, plus an HPE specific CPXXXX.xml file.

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change.

To obtain the guide:

  1. Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

#esxcli software vib remove lpfc

Supported Devices and Features:

This component is supported on following Emulex Converged Network Adapters:

XE100 Series:

  • HP StoreFabric CN1200E Dual Port Converged Network Adapter
  • HP FlexFabric 20Gb 2-port 650FLB Adapter
  • HP FlexFabric 20Gb 2-port 650M Adapter
  • HPE StoreFabric CN1200E-T Adapter

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Servers do not complete the process to connect to OneConnectManager Management Host On Windows 2008/ 2012 and 2016

This component is intended to be used by HPE applications. It is a zip that contains the same driver deliverable available from the vmware.com and the HPE vibsdepot.hpe.com webpages, plus an HPE specific CPXXXX.xml file.

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change.

To obtain the guide:

  1. Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

#esxcli software vib remove lpfc

Version:2019.03.03 (25 Jul 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Servers do not complete the process to connect to OneConnectManager Management Host On Windows 2008/ 2012 and 2016

.Updated to Driver version 12.0.1216.4


Version:2019.03.01 (2 Apr 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Added workaround to reduce the race probability in Input Output Device Management (IODM).
  • VMWare vSphere 6.7 Update 1 becomes unresponsive to commands like “esxtop” and “esxcli storage core adapter list” after vmkfstool bus and target reset.
  • Fixed Purple Screen of Death (PSOD) Triggered by assert that when destroying a Slab and there was still one object not released.

Added support for VMWare vSphere 6.7 Update 1.

Updated to Driver version 12.0.1211.0


Version:2018.11.01 (27 Nov 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Updated to Driver version 12.0.1115.0


Version:2018.06.01 (27 Jun 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Updated to Driver version 12.0.1115.0


Version:2018.02.01 (19 Apr 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Initial release supporting VMware vSphere 6.7

Driver version 12.0.1113.0


Type:Software - Storage Fibre Channel and Fibre Channel Over Ethernet
Version:2019.03.03(25 Jul 2019)
Operating System(s):
VMware vSphere 6.7

Description

VMware vSphere 6.7 Fibre Channel over Ethernet Driver kit for HPE Emulex(BRCM) Converged Network Adapters

Enhancements

Installation Instructions

Prerequisites:

Please consult SPOCK for a list of supported configurations available at the following link:

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change.

To obtain the guide:

  1. Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

#esxcli software vib remove lpfc

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

9712c3d5c75daf20560bb9b49f6f4ab1fa37b84a51dd6b8cf51adf35b7a90bcacp040416.zip
d5ea031931cbce8a639b488ef785be07d9795838c05c5e58e063ca30c2e982a4cp040416.compsig

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

To use Smart Update Manager from the Service Pack for ProLiant:

Remote Online, if the component is supported by SUM but is not yet part of an SPP:

  • Download the appropriate Service Pack for ProLiant
  • Add the component to the Service Pack for ProLiant
  • Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated
  • Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux
  • Add the ESXi host to be updated as a remote target/node
  • Enter the IP or DNS address of the ESXi host to be updated
  • Enter the ESXi host credentials (root or administrator username and password)
  • For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.
  • Follow Smart Update Manager Steps and complete the firmware update.
  • Refer to the Service Pack for ProLiant Documentation for detailed instructions at: www.hpe.com/servers/spp/download

To update the driver using VMware tools:

  • Unzip this HPE component to extract the driver offline bundle
  • Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.
  • Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands

Release Notes

End User License Agreements:
HPE Software License Agreement v1

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Important:

This component is intended to be used by HPE applications. It is a zip that contains the same driver deliverable available from the vmware.com and the HPE vibsdepot.hpe.com webpages, plus an HPE specific CPXXXX.xml file.

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change.

To obtain the guide:

  1. Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

#esxcli software vib remove lpfc

Supported Devices and Features:

This component is supported on following Emulex Converged Network Adapters:

XE100 Series:

  • HP StoreFabric CN1200E Dual Port Converged Network Adapter
  • HP FlexFabric 20Gb 2-port 650FLB Adapter
  • HP FlexFabric 20Gb 2-port 650M Adapter
  • HPE StoreFabric CN1200E-T Adapter

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Servers do not complete the process to connect to OneConnectManager Management Host On Windows 2008/ 2012 and 2016

Important

This component is intended to be used by HPE applications. It is a zip that contains the same driver deliverable available from the vmware.com and the HPE vibsdepot.hpe.com webpages, plus an HPE specific CPXXXX.xml file.

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change.

To obtain the guide:

  1. Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

If the server contains only CNA adapters and lpfc driver is already been installed, post the new driver update, please remove the lpfc driver using the following command:

#esxcli software vib remove lpfc

Revision History

Version:2019.03.03 (25 Jul 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Servers do not complete the process to connect to OneConnectManager Management Host On Windows 2008/ 2012 and 2016

.Updated to Driver version 12.0.1216.4


Version:2019.03.01 (2 Apr 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Added workaround to reduce the race probability in Input Output Device Management (IODM).
  • VMWare vSphere 6.7 Update 1 becomes unresponsive to commands like “esxtop” and “esxcli storage core adapter list” after vmkfstool bus and target reset.
  • Fixed Purple Screen of Death (PSOD) Triggered by assert that when destroying a Slab and there was still one object not released.

Added support for VMWare vSphere 6.7 Update 1.

Updated to Driver version 12.0.1211.0


Version:2018.11.01 (27 Nov 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Updated to Driver version 12.0.1115.0


Version:2018.06.01 (27 Jun 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Updated to Driver version 12.0.1115.0


Version:2018.02.01 (19 Apr 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Initial release supporting VMware vSphere 6.7

Driver version 12.0.1113.0


Emulex OneCommand Manager 5.0 Pdf User Manuals. View online or download Emulex OneCommand Manager 5.0 User Manual. Manuals; Brands; Emulex Manuals. In A VMware ESX Server With An Existing HBAnyware CLI Kit Installed 17. Emulex Driver For Linux And OneCommand Manager Application Situations 219. Downloads Free! 76 Drivers and Manual for Emulex LPe12000 Networks Cards. Here's where you can download Free! The newest software for your LPe12000. . RECOMMENDED. Emulex Fibre Channel driver component for VMware vSphere 6.7. By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a.

Vmware update drivers

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

Printable version

* RECOMMENDED * HPE Firmware Flash for Emulex Converged Network Adapters for VMware vSphere 6.0

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type:Firmware - Network
Version:2019.03.01(2 Apr 2019)
Operating System(s): VMware vSphere 6.0
Multi-part download
File name:CP035745.compsig (2.2 KB)
File name:CP035745.zip (6.2 MB)
This component upgrades the operating firmware for Converged Network and Network only adapters.

Updated CNA (XE100 series) firmware

Firmware

Contains:

CNA (XE100 series) firmware 12.0.1216.0

Prerequisites:

Please consult SPOCK for a list of supported configurations available at the following link:

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

49a18ef413dca7c63448e5d2ad74137e05bfd4877217fff29c23c7c250b6db97CP035745.compsig
6c6abca5df9fdd1a1a8a306cac4e07779e442d9277500ef9ff2e68d5bee27435CP035745.zip

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

To use Smart Update Manager from the Service Pack for ProLiant:

Offline:

  • Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components

Remote Online, if the component is supported by SUM but is not yet part of an SPP:

  • Download the appropriate Service Pack for ProLiant
  • Add the component to the Service Pack for ProLiant
  • Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated
  • Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux
  • Add the ESXi host to be updated as a remote target/node
  • Enter the IP or DNS address of the ESXi host to be updated
  • Enter the ESXi host credentials (root or administrator username and password)
  • For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.
  • Follow Smart Update Manager Steps and complete the firmware update.
  • Refer to the Service Pack for ProLiant Documentation for detailed instructions at: www.hpe.com/servers/spp/download

To use HPE Insight Control for vCenter :

  • Log in to the vSphere Client.
  • Select a server or cluster in the inventory tree.
  • Click the HPE Insight Management tab.
  • Follow Insight Control for vCenter steps to update firmware using a Smart Component

To update firmware from VMware ESXi operating system on target server:

  • Enable Tech Support Mode on the ESXi host.
  • Login as root. (You must be root in order to apply the ROM update.)
  • Place the Smart Component (CPxxxxxx.zip) in a temporary directory.
  • From the same directory, unzip the Smart Component.
    • unzip CPxxxxxx.zip
  • Ensure that the file CPxxxxxx.vmexe is executable. Execute the command:
    • chmod +x CPxxxxxx.vmexe
  • To perform the standalone installation, execute the command:
    • ./CPxxxxxx.vmexe
  • Follow the directions given by the Smart Component
  • Logout
  • Disable Tech Support Mode on the ESXi host
  • Reboot your system, if required, for the firmware update to take effect

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Important:

Release Notes:

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change.

To obtain the guide:

  1. Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

Supported Devices and Features:

This component is supported on following Emulex Converged Network Adapters:

XE100 Series:

  • HP StoreFabric CN1200E Dual Port Converged Network Adapter
  • HP FlexFabric 20Gb 2-port 650FLB Adapter
  • HP FlexFabric 20Gb 2-port 650M Adapter
  • HPE StoreFabric CN1200E-T Adapter

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Fixed unexpected behavior in Active Health System (AHS) logs show World Wide Node Name (wwnn) & World Wide Port Name (wwpn) in reverse order.
  • Microsoft Windows Server 2012 R2 Hyper-V Storage Area Network (SAN) Disconnect.
  • Link lost with firmware version 11.2.1263.19
  • 'FW not responding” message seen on card when creating Virtual Function (VF) in loop for HPE StoreFabric CN1200E-T 10GBASE-T Converged Network Adapter [NIC+ iSCSI] in Gen10 server.
  • HP FlexFabric 20Gb 2-port 650FLB Adapter - Loss of access to storage after Virtual Connect (VC) login redistribution
  • HP StoreFabric CN1200E Dual Port Converged Network Adapter does not complete to boot in Legacy Mode on Gen 9 Server
  • Emulex Peripheral Component Interconnect (PCI) slot Network Interface Connector (NIC) reported as device path instead of product name
  • Unable to disable shared memory feature in Human Interface Infrastructure (HII) menu
  • 650M Adapter has some info in Chinese and Japanese show garbled code under Human Interface Infrastructure (HII) Form

Release Notes:

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change.

To obtain the guide:

  1. Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

Version:2019.03.01 (2 Apr 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Fixed unexpected behavior in Active Health System (AHS) logs show World Wide Node Name (wwnn) & World Wide Port Name (wwpn) in reverse order.
  • Microsoft Windows Server 2012 R2 Hyper-V Storage Area Network (SAN) Disconnect.
  • Link lost with firmware version 11.2.1263.19
  • 'FW not responding” message seen on card when creating Virtual Function (VF) in loop for HPE StoreFabric CN1200E-T 10GBASE-T Converged Network Adapter [NIC+ iSCSI] in Gen10 server.
  • HP FlexFabric 20Gb 2-port 650FLB Adapter - Loss of access to storage after Virtual Connect (VC) login redistribution
  • HP StoreFabric CN1200E Dual Port Converged Network Adapter does not complete to boot in Legacy Mode on Gen 9 Server
  • Emulex Peripheral Component Interconnect (PCI) slot Network Interface Connector (NIC) reported as device path instead of product name
  • Unable to disable shared memory feature in Human Interface Infrastructure (HII) menu
  • 650M Adapter has some info in Chinese and Japanese show garbled code under Human Interface Infrastructure (HII) Form

Updated CNA (XE100 series) firmware

Firmware

Contains:

CNA (XE100 series) firmware 12.0.1216.0


Version:2018.09.01 (27 Sep 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

We have separate components to update fibre channel and converged network adapters. This is a converged network adapter update component

Updated CNA (XE100 series) firmware

Firmware

Contains:

CNA (XE100 series) firmware 12.0.1110.11


Version:2018.06.01 (26 Jun 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Add a check for zero capacity LUNs (Logical Units) and avoid creating device path for them.
  • HP StoreFabric CN1200E Dual Port Converged Network Adapter FCoE function only show 'Slot 3 Port 3:CN1200E Function 2-FCoE'

We have separate components to update fibre channel and converged network adapters. This is a Converge Network Adapter update component.

Updated CNA (XE100 series) firmware

Firmware

Contains:

CNA (XE100 series) firmware 12.0.1110.11


Version:2018.02.01 (5 Feb 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

UEFI:

  • Boot From SAN(BFS) volume is seen offline during Microsoft Windows 2016 Operating System install with 11.2.1263.19 Firmware
  • Removal of Boot entry from card Basic Input /Output System(BIOS) caused a red screen on HPE ProLiant ML350 Gen10 Server

BIOS/Firmware:

  • HP FlexFabric 20Gb 2-port 650M Adapter goes missing from Operating System (OS) post 1.1.183.624 firmware flash
  • Excessive number of timeouts overflowing Noted All or Nothing Gate(NAND)
  • For HP StoreFabric CN1200E 10Gb Converged Network Adapter and HPE StoreFabric CN1200E-T 10GBASE-T Converged Network Adapter Firmware Active Health System (AHS) log incorrect part number
  • Name of HP StoreFabric CN1200E 10Gb Converged Network Adapter show incomplete in Active Health System (AHS)
  • For HP FlexFabric 20Gb 2-port 650FLB Adapter “Function Driver” is missing in Active Health System (AHS) field
  • Ports of HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter/HPE StoreFabric CN1200E-T 10GBASE-T Converged Network Adapter will become Disconnected in ESXI6.0 update 3 Operating System
  • Server Profile Health Status is not stable during Power on

Added support for the following:

UEFI:

  • Modify Fibre Channel over Ethernet (FCoE) code base to compile with Unreal Development Kit 2015(UDK2015) for access to new Unified Extensible Firmware Interface (UEFI)
  • Implement HP Unified Extensible Firmware Interface (UEFI) reqs - spec changes from 2.2 and 2.3

Firmware:

  • Security Encryption for Internet Small Computer System Interface(iSCSI) Challenge Handshake Authentication Protocol (CHAP) and Data Center Interconnect(DCi) config data
  • Platform Management Components Intercommunication (PMCI) v1.1.0 - which also covers Network Controller Sideband Interface (NC-SI) requirements V1.01
  • Active Health System (AHS) Device Capabilities support in the Auxiliary Port (Aux) power

Updated CNA (XE100 series) firmware:

Contains:

CNA (XE100 series) firmware 11.4.1231.6


Version:2017.09.01 (25 Sep 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Resolves unexpected behavior where 650 FLB and M adapters throw 'PCIe Link Bandwidth Reduction' events
  • Resolves unexpected behavior where 650M adapter goes missing from OS post Hotfix FW flash of 11.1.183 build 32
  • Fixed the unexpected behavior where HP BL460c Gen10 system is powered off after flashing 11.2.1223.0 firmware and iLO5 Thermal tab is reporting Overheating temperature 122C for 650FLB adapter
  • Resolves an unexpected behavior where Network adapters has no network information inActive Health System (AHS) logs.

Updated CNA (XE100 series) firmware

Contains:

CNA (XE100 series) firmware 11.2.1263.19


Version:2017.06.01 (12 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Resolves the following:

• HPE FlexFabric 20Gb 650FLB Adapter using 10.2 driver/firmware NICs went into an incomplete state
• HPE FlexFabric 20Gb 650FLB Adapter in which multiple Virtual Connect links could result in an unexpected termination of the Windows Operating System

Added support for the following:


• HPE UEFI 2.0
• Data Center interconnect (Dci) / Active Service Network (ASN) configuration defaults.
• NIC Discovery and Configuration via iLO
• Single Transmit(TX) queue for Bandwidth(BW) capping with multiple Receive(Rx) queues for Receive Side Scaling (RSS) via Linux NIC Driver
• Ability to notify user that OneView is already in control of the adapter when OneCommand Manager (OCM) is loaded.

Support for following specs:


a. Inter-IC(I2C) Interface Spec v2.01
b. Data Center interconnect (Dci) spec
c. Abstract Syntax Notation One (ASN.1)

Updated CNA (XE100 series) Firmware

Contains:

CNA (XE100 series) firmware 11.2.1226.20


Type:Firmware - Network
Version:2019.03.01(2 Apr 2019)
Operating System(s):
VMware vSphere 6.0

Description

This component upgrades the operating firmware for Converged Network and Network only adapters.

Enhancements

Updated CNA (XE100 series) firmware

Firmware

Contains:

CNA (XE100 series) firmware 12.0.1216.0

Installation Instructions

Prerequisites:

Please consult SPOCK for a list of supported configurations available at the following link:

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

49a18ef413dca7c63448e5d2ad74137e05bfd4877217fff29c23c7c250b6db97CP035745.compsig
6c6abca5df9fdd1a1a8a306cac4e07779e442d9277500ef9ff2e68d5bee27435CP035745.zip

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

To use Smart Update Manager from the Service Pack for ProLiant:

Offline:

  • Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components

Remote Online, if the component is supported by SUM but is not yet part of an SPP:

  • Download the appropriate Service Pack for ProLiant
  • Add the component to the Service Pack for ProLiant
  • Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated
  • Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux
  • Add the ESXi host to be updated as a remote target/node
  • Enter the IP or DNS address of the ESXi host to be updated
  • Enter the ESXi host credentials (root or administrator username and password)
  • For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.
  • Follow Smart Update Manager Steps and complete the firmware update.
  • Refer to the Service Pack for ProLiant Documentation for detailed instructions at: www.hpe.com/servers/spp/download

To use HPE Insight Control for vCenter :

  • Log in to the vSphere Client.
  • Select a server or cluster in the inventory tree.
  • Click the HPE Insight Management tab.
  • Follow Insight Control for vCenter steps to update firmware using a Smart Component

To update firmware from VMware ESXi operating system on target server:

  • Enable Tech Support Mode on the ESXi host.
  • Login as root. (You must be root in order to apply the ROM update.)
  • Place the Smart Component (CPxxxxxx.zip) in a temporary directory.
  • From the same directory, unzip the Smart Component.
    • unzip CPxxxxxx.zip
  • Ensure that the file CPxxxxxx.vmexe is executable. Execute the command:
    • chmod +x CPxxxxxx.vmexe
  • To perform the standalone installation, execute the command:
    • ./CPxxxxxx.vmexe
  • Follow the directions given by the Smart Component
  • Logout
  • Disable Tech Support Mode on the ESXi host
  • Reboot your system, if required, for the firmware update to take effect

Release Notes

End User License Agreements:
HPE Software License Agreement v1
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Important:

Release Notes:

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change.

To obtain the guide:

  1. Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

Supported Devices and Features:

This component is supported on following Emulex Converged Network Adapters:

XE100 Series:

  • HP StoreFabric CN1200E Dual Port Converged Network Adapter
  • HP FlexFabric 20Gb 2-port 650FLB Adapter
  • HP FlexFabric 20Gb 2-port 650M Adapter
  • HPE StoreFabric CN1200E-T Adapter

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Fixed unexpected behavior in Active Health System (AHS) logs show World Wide Node Name (wwnn) & World Wide Port Name (wwpn) in reverse order.
  • Microsoft Windows Server 2012 R2 Hyper-V Storage Area Network (SAN) Disconnect.
  • Link lost with firmware version 11.2.1263.19
  • 'FW not responding” message seen on card when creating Virtual Function (VF) in loop for HPE StoreFabric CN1200E-T 10GBASE-T Converged Network Adapter [NIC+ iSCSI] in Gen10 server.
  • HP FlexFabric 20Gb 2-port 650FLB Adapter - Loss of access to storage after Virtual Connect (VC) login redistribution
  • HP StoreFabric CN1200E Dual Port Converged Network Adapter does not complete to boot in Legacy Mode on Gen 9 Server
  • Emulex Peripheral Component Interconnect (PCI) slot Network Interface Connector (NIC) reported as device path instead of product name
  • Unable to disable shared memory feature in Human Interface Infrastructure (HII) menu
  • 650M Adapter has some info in Chinese and Japanese show garbled code under Human Interface Infrastructure (HII) Form

Important

Release Notes:

Beginning with software release 11.2, Fibre Channel (LightPulse) adapters and Converged Network adapters (OneConnect) have independent software kits.

It is highly recommended that you review the Broadcom Software Kit Migration User Guide for more detailed information regarding this change.

To obtain the guide:

  1. Go to http://www.hpe.com/support/manuals
  2. Using the HPE model number as your guide, enter the adapter model number in the Search products box, and then click >>.

This document provides special instructions and considerations for using the driver kits for FC and CNA adapters.

Special cases include those in which pre-11.2 (original) drivers and applications are replaced by the new 11.2 drivers and applications, and cases in which inbox drivers are replaced by the new 11.2 out-of-box (OOB) drivers.

Revision History

Version:2019.03.01 (2 Apr 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Fixed unexpected behavior in Active Health System (AHS) logs show World Wide Node Name (wwnn) & World Wide Port Name (wwpn) in reverse order.
  • Microsoft Windows Server 2012 R2 Hyper-V Storage Area Network (SAN) Disconnect.
  • Link lost with firmware version 11.2.1263.19
  • 'FW not responding” message seen on card when creating Virtual Function (VF) in loop for HPE StoreFabric CN1200E-T 10GBASE-T Converged Network Adapter [NIC+ iSCSI] in Gen10 server.
  • HP FlexFabric 20Gb 2-port 650FLB Adapter - Loss of access to storage after Virtual Connect (VC) login redistribution
  • HP StoreFabric CN1200E Dual Port Converged Network Adapter does not complete to boot in Legacy Mode on Gen 9 Server
  • Emulex Peripheral Component Interconnect (PCI) slot Network Interface Connector (NIC) reported as device path instead of product name
  • Unable to disable shared memory feature in Human Interface Infrastructure (HII) menu
  • 650M Adapter has some info in Chinese and Japanese show garbled code under Human Interface Infrastructure (HII) Form

Updated CNA (XE100 series) firmware

Firmware

Contains:

CNA (XE100 series) firmware 12.0.1216.0


Version:2018.09.01 (27 Sep 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

We have separate components to update fibre channel and converged network adapters. This is a converged network adapter update component Sony walkman nwz e438f user manual.

Updated CNA (XE100 series) firmware

Firmware

Contains:

CNA (XE100 series) firmware 12.0.1110.11


Version:2018.06.01 (26 Jun 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Add a check for zero capacity LUNs (Logical Units) and avoid creating device path for them.
  • HP StoreFabric CN1200E Dual Port Converged Network Adapter FCoE function only show 'Slot 3 Port 3:CN1200E Function 2-FCoE'

We have separate components to update fibre channel and converged network adapters. This is a Converge Network Adapter update component.

Updated CNA (XE100 series) firmware

Firmware

Contains:

CNA (XE100 series) firmware 12.0.1110.11


Version:2018.02.01 (5 Feb 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

UEFI:

  • Boot From SAN(BFS) volume is seen offline during Microsoft Windows 2016 Operating System install with 11.2.1263.19 Firmware
  • Removal of Boot entry from card Basic Input /Output System(BIOS) caused a red screen on HPE ProLiant ML350 Gen10 Server

BIOS/Firmware:

  • HP FlexFabric 20Gb 2-port 650M Adapter goes missing from Operating System (OS) post 1.1.183.624 firmware flash
  • Excessive number of timeouts overflowing Noted All or Nothing Gate(NAND)
  • For HP StoreFabric CN1200E 10Gb Converged Network Adapter and HPE StoreFabric CN1200E-T 10GBASE-T Converged Network Adapter Firmware Active Health System (AHS) log incorrect part number
  • Name of HP StoreFabric CN1200E 10Gb Converged Network Adapter show incomplete in Active Health System (AHS)
  • For HP FlexFabric 20Gb 2-port 650FLB Adapter “Function Driver” is missing in Active Health System (AHS) field
  • Ports of HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter/HPE StoreFabric CN1200E-T 10GBASE-T Converged Network Adapter will become Disconnected in ESXI6.0 update 3 Operating System
  • Server Profile Health Status is not stable during Power on

Added support for the following:

UEFI:

  • Modify Fibre Channel over Ethernet (FCoE) code base to compile with Unreal Development Kit 2015(UDK2015) for access to new Unified Extensible Firmware Interface (UEFI)
  • Implement HP Unified Extensible Firmware Interface (UEFI) reqs - spec changes from 2.2 and 2.3

Firmware:

  • Security Encryption for Internet Small Computer System Interface(iSCSI) Challenge Handshake Authentication Protocol (CHAP) and Data Center Interconnect(DCi) config data
  • Platform Management Components Intercommunication (PMCI) v1.1.0 - which also covers Network Controller Sideband Interface (NC-SI) requirements V1.01
  • Active Health System (AHS) Device Capabilities support in the Auxiliary Port (Aux) power

Updated CNA (XE100 series) firmware:

Contains:

CNA (XE100 series) firmware 11.4.1231.6


Version:2017.09.01 (25 Sep 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed the following:

  • Resolves unexpected behavior where 650 FLB and M adapters throw 'PCIe Link Bandwidth Reduction' events
  • Resolves unexpected behavior where 650M adapter goes missing from OS post Hotfix FW flash of 11.1.183 build 32
  • Fixed the unexpected behavior where HP BL460c Gen10 system is powered off after flashing 11.2.1223.0 firmware and iLO5 Thermal tab is reporting Overheating temperature 122C for 650FLB adapter
  • Resolves an unexpected behavior where Network adapters has no network information inActive Health System (AHS) logs.

Updated CNA (XE100 series) firmware

Contains:

CNA (XE100 series) firmware 11.2.1263.19


Version:2017.06.01 (12 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Resolves the following:

• HPE FlexFabric 20Gb 650FLB Adapter using 10.2 driver/firmware NICs went into an incomplete state
• HPE FlexFabric 20Gb 650FLB Adapter in which multiple Virtual Connect links could result in an unexpected termination of the Windows Operating System

Added support for the following:


• HPE UEFI 2.0
• Data Center interconnect (Dci) / Active Service Network (ASN) configuration defaults.
• NIC Discovery and Configuration via iLO
• Single Transmit(TX) queue for Bandwidth(BW) capping with multiple Receive(Rx) queues for Receive Side Scaling (RSS) via Linux NIC Driver
• Ability to notify user that OneView is already in control of the adapter when OneCommand Manager (OCM) is loaded.

Support for following specs:


a. Inter-IC(I2C) Interface Spec v2.01
b. Data Center interconnect (Dci) spec
c. Abstract Syntax Notation One (ASN.1)

Updated CNA (XE100 series) Firmware

Contains:

CNA (XE100 series) firmware 11.2.1226.20


Add Drivers To Esxi Installer

User

Vmware Nic Drivers

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.